| Application | ||
| Thermal Current Rating | 100A | 125A |
| Intermittent Current Rating: | ||
| 30% Duty | 185A | 230A |
| 40% Duty | 160A | 200A |
| 50% Duty | 140A | 175A |
| 60% Duty | 130A | 160A |
| 70% Duty | 120A | 150A |
|
Rated Fault Current Breaking Capacity (Icn) 5ms Time Constant: |
||
| Blowouts | 600A at 80V D.C. | |
| No Blowouts | 800A at 48V D.C. | |
|
Rated Fault Current Breaking Capacity (Icn) Resistive Load: |
||
| Blowouts | - | |
| No Blowouts | - | |
| Maximum Recommended Contact Voltages | ||
| Blowouts | 96V | 96V |
| No Blowouts | 48V | 48V |
| Typical Voltage Drop per pole across New Contacts at 100A | 50mV | |
| Mechanical Durability | > 5,000,000 Cycles | |
| Coil Voltage Available (Us) (Rectifier board required for A.C.) | 6 - 240V | |